Manufacturers of quality liquid measurement meters, AMCO industrial products include:
• Cold water meters
• Hot water meters
• Oil meters
• Stainless steel meters for chemicals
• Process batch controls
|
|
All meters indicate flow rate and totalization.
Available in USG, cu. ft. or M3.
Optional items:
Pulsers, counters, rate of flow electronics and chart measuring capability.
|
|
|
|
|
Electronic Register Specifications: C-700, 1/2" thru 2" and T-3000, 1-1/2" thru 12"
|
 |
DISPLAYS RATE &TOTAL 4 1/2 Digit Rate Display 8 Digit Total Display
TOTALVOLUME IS RESETTABLE Remote and/or Local Reset
OPTIONS 4-20 MADC Analog Output External Power Supply
Scalable Pulse Output Signal Linearization Remote Reset
TAMPER-PROOF Cover must be removed to alter programming. Lockout code required to enter program
PRE-PROGRAMMED FOR YOUR FLOW METER
UPGRADES EXISTING FLOW METER IN THE FIELD
POWERED BY INTERNAL BATTERY, EXTERNAL DC POWER OR BY A 4-20 MADC SIGNAL LOOP
DESCRIPTION
The Electronic Register (ER) is an LCD display which has been installed in an aluminum, watertight housing easily adapted for installation on ABB's C-700, T-3000 and WP4000 cold water meters.
The ER is designed to replace mechanical registers with LCD displays of rate indication and totalization in the basic unit. |
SPECIFICATIONS
POWER:
Battery Powered One C size lithium battery External Power Input Option Voltage - 8.5 to 30 VDC Current - Less than 5 MADC
Protection - Reverse polarity protected Loop Powered
Voltage - 8.5 to 30 VDC Loop Burden - 8.5 VDC Protection - Reverse polarity protected
DISPLAY:
Rate Display
LCD, 4.5 digits (59999), 0.35" h.
Display updates every 2 seconds Rate Descriptors: /SEC, /MIN, /HR Totalizer Display
LCD, 8 digits (99999999), 0.2" h.
Multipliers: x10, x100, x1000 Total Descriptors: GAL, LIT, FT#, M3, "blank"
NOTE: Rate of Flow indication for the T3000 series meters requires flow rates above the listed minimum flows of the specification sheets, (totalization is not affected). Please call Customer Service for additional information. |
|
|
AquaMaster, Electronic Water Meter Specifications: Sizes 2" to 12"
|
AquaMaster's Principle of Operation
It measures flow of water in pipes by using Faraday's principle of magnetic induction: a conductor (water) moving through a magnetic field will induce an electric current proportional to the velocity of the conductor. Water volume through the meter can then be easily calculated.
Widest flow range, highest accuracy (up to 1500:1 turndown)
Measures minimal night and peak day flows
Lowest cost of ownership
Rugged construction with no moving parts
Ensures long, maintenance free life
"Fit and Flow""'
Foolproof installation; no on-site setup
Battery operation
3 year life
No external power supply required, facilitates installation in remote locations |
 |
AC powered with optional battery backup
Continuous measurement even during power-down
Integral or Remote Electronic Display Unit
All user display requirements in a single unit
Submersible sensor and Electronic Display Unit
Facilitates installation in all locations including flooded pits.
Buriable sensor
Eliminates chamber and ensures fast, low cost installation
Wetted materials
Lining- Elastomer (UKWFBS Listed)
Electrodes- Stainless steel 316 L
Pressure Limitations
As flange rating
Conductivity
50mS/cm
End Connections
Flanged
ANSI B 16.5 1.5 Class 150
|
|
|